MSFM flow meter is a highly accurate ultrasonic area velocity MCERTS certified flow meter for open channel monitoring and part filled pipes.
The MSFM MCERTS Area Velocity flow meter is a self-contained battery powered insertion multi-sensor flow meter and is certified to deliver guaranteed flow measurement accuracy for sites which require verification by MCERTS inspectors.
Portable and easily installed, it can be used for short term or long term flow monitoring programs.
Suitable applications include:
› Wastewater Monitoring
› Effluent Monitoring
› Environmental Permit Regulations (EPR)
› Inflow and Infiltration
› Flood Prevention
› Pollution Control
› Pass Forward Flows to full treatment
› Discharge Management
Detectronic’s dedicated data centre monitors your network and uses your data to detect blockages before they cause flooding and pollution.
› Real time data collection and monitoring helps you better understand your sewer network.
› Using human Intelligence means you only receive validated intervention reports
› Site data, MET office data and local environmental data is integrated for every site
› Highly Compatible with data from any make of telemetered monitors
Power | Battery Powered (Upto 5 Years Life Expectancy) |
Sensor Type | Velocity, Depth, Temperature |
Velocity Sensor Type | dual piezoelectric elements |
Velocity Range | 0.03m/s to 4.00m/s (resolution 1mm/s) |
Velocity Linearity | ±1% |
Velocity Accuracy | ±2.5% FS |
Depth Sensor Type | hydrostatic pressure |
Depth Range | 0.0m to 3.5m (resolution 1.0mm) |
Depth Sensor Linearity | 0.1% BSL |
Depth Sensor Accuracy | ±0.2% FS |
Sensor Type | titanium diaphragm isolated silicon sensor |
Temperature Range | -20°C to 60°C |
Certification | MCERT |
Storage | solid state 128k-40k per channel (rotating store or store until full) |
Data Transmission | 2G/3G GSM/GPRS communication |
The MSFM MCERTS is accredited by the Environment Agency and is the ideal monitoring system for any business, industry or water company that falls within the Environmental Permitting Regulations (EPR).
It enables companies to understand exactly what is happening with their agreed consented discharge at any given time. Any flow greater than 50 cubic meters per day must be monitored with MCERTS accredited technology according to the Environment Agency’s Self-Monitoring Certification Scheme.
Water companies can use it to precisely monitor Pump Station Emergency overflow. Wastewater treatment works can measure compliance with Pass forward flow (PFF) to full treatment and for final discharge. It can also be employed in clean water reservoirs.